Lenovo ThinkSystem SR655 with AMD EPYC 2U Rack Server

PROCESSORS:
One socket AMD EPYC Processors

RAM:
16x TruDDR4 memory DIMMs with one processor
The server supports these memory DIMMs:
2933 MHz DIMMs, that operate at 2933 MHz both at 1 DIMM per channel and 2 DIMMs per channel
3200 MHz DIMMs, that operate at 3200 MHz at 1 DIMM per channel, and at 2933 MHz at 2 DIMMs per channel
Memory Supported 8GB 16GB 32GB 64GB
The server supports up to 1TB of memory using 16x 64 GB RDIMMs

INTERNAL STORAGE:
3.5inch drive bays:
No drives and no backplane supports field upgrades
a 8x 3.5inch SASSATA no upgrades
b 12x 3.5inch SASSATA no upgrades
c8x 3.5inch SASSATA 4x 3.5inch AnyBay AnyBay supports SAS or SATA or NVMe drives no upgrades
2.5inch drive bays
a No drives and no backplane supports field upgrades
b 8x 2.5inch SASSATA supports field upgrades to 16 or 24 drives
c 16x 2.5inch SASSATA supports field upgrades to 24 drives
d 24x 2.5inch SASSATA no upgrades
e 8x 2.5inch NVMe supports field upgrades to 16 or 24 drives
f 16x 2.5inch NVMe supports field upgrades to 24 drives
g 24x 2.5inch NVMe no upgrades
h 8x 2.5inch NVMe 8x 2.5inch SASSATA supports upgrade to 16x SASSATA
i 8x 2.5inch NVMe 16x 2.5inch SASSATA no upgrades
Mid drive bays:
a 4x 3.5inch hotswap SASSATA drive bays
b 8x 2.5inch hotswap SASSATA drive bays
c 8x 2.5inch hotswap NVMe drive bays
Rear drive bays:
a 4x 3.5inch hotswap SASSATA drive bays
b 4x 2.5inch hotswap SASSATA drive bays
c 4x 2.5inch hotswap NVMe drive bays

CONTROLLER OPTIONS:
6 Gbps SATA controllers:
Onboard AHCI nonRAID Intel RSTe RAID
12 Gb SASSATA RAID controllers:
ThinkSystem RAID 5308i PCIe 12Gb Adapter
ThinkSystem RAID 7308i 1GB Cache PCIe 12Gb Adapter
ThinkSystem RAID 7308i 2GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 9308i 2GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 93016i 4GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 93016i 8GB Flash PCIe 12Gb Adapter
12 Gb SASSATA nonRAID HBAs:
ThinkSystem 4308i SASSATA 12Gb HBA
ThinkSystem 43016i SASSATA 12Gb HBA
NVMe PCIe interfaces nonRAID:
ThinkSystem 8104P NVMe Switch Adapter
ThinkSystem 16104P NVMe Switch Adapter

IO EXPANSION:
Riser 1: Slots 1, 2 and 3 all FHHL or FHFL 16 or 32 lanes:
a Option 1: x16, x8, x8 all physically x16 slots
b Option 2: x16, x16, NC slot 3 not connected
c Option 3: NC, NC, x16 1U riser; slot 1 and slot 2 not connected
d Option 4: x16, NC, NC slot 2 and slot 3 not connected
Riser 2: Slots 4, 5, and 6 slot size varies 32 lanes
a Option 1: x16, x8, x8 all physically x16 slots
b Option 2: x16, x16, NC slot 6 not connected
d Option 3: NC, NC, x16 1U riser; slot 4 and slot 5 not connected
Riser 3: Slots 7 and 8 both FHHL or FHFL 16 or 32 lanes
a Option 1: x8, x8 both physically x16 slots
b Option 2: x16, x16
Slot 9: Internal PCIe 4.0 x8 lowprofile slot for internal drive controller physically a x16 slot
WARNING:
The use of 32 lanes with Riser 1 or the use of Riser 3 or Slot 9 imposes restrictions on the use of the onboard SATA
controller or the use of the M.2 Module or both
NETWORK ADAPTERS:
Network adapters options:
1 Gb Ethernet
10 Gb Ethernet
PCIe Low Profile adapters 25 Gb Ethernet
InfiniBand
SAS adapters for external storage:
SAS HBAs
ThinkSystem 4308e SASSATA 12Gb HBA
ThinkSystem 43016e SASSATA 12Gb HBA
External RAID adapters
ThinkSystem RAID 9308e 4GB Flash PCIe 12Gb Adapter

GPU adapter:
ThinkSystem NVIDIA Tesla V100 16GB PCIe Passive GPU
ThinkSystem NVIDIA Tesla V100 32GB PCIe Passive GPU
ThinkSystem NVIDIA Tesla T4 16GB PCIe Passive GPU

POWER SUPPLIES:
1 or 2 ThinkSystem 550W 230V115V Platinum HotSwap PSU
1 or 2 ThinkSystem 750W 230115V Platinum HotSwap PSU
1 or 2 ThinkSystem 1100W Platinum HotSwap PSU
1 or 2 ThinkSystem 1600W Platinum HotSwap PSU

ZA VEC INFORMACIJ OBIáCITESTRAN:

ZA PONUDBO KLIKNITE POLJE ELIM PONUDBO

ZA POMOî NAS POKLICITE ALI PA NAM POáLJITE EMAIL
KODA: 7Z01CTO1WW
Zaloga:

Podrobnosti artikla

Podrobnosti

PROCESSORS:
One socket AMD EPYC Processors

RAM:
16x TruDDR4 memory DIMMs with one processor
The server supports these memory DIMMs:
2933 MHz DIMMs, that operate at 2933 MHz both at 1 DIMM per channel and 2 DIMMs per channel
3200 MHz DIMMs, that operate at 3200 MHz at 1 DIMM per channel, and at 2933 MHz at 2 DIMMs per channel
Memory Supported 8GB 16GB 32GB 64GB
The server supports up to 1TB of memory using 16x 64 GB RDIMMs

INTERNAL STORAGE:
3.5inch drive bays:
No drives and no backplane supports field upgrades
a 8x 3.5inch SASSATA no upgrades
b 12x 3.5inch SASSATA no upgrades
c8x 3.5inch SASSATA 4x 3.5inch AnyBay AnyBay supports SAS or SATA or NVMe drives no upgrades
2.5inch drive bays
a No drives and no backplane supports field upgrades
b 8x 2.5inch SASSATA supports field upgrades to 16 or 24 drives
c 16x 2.5inch SASSATA supports field upgrades to 24 drives
d 24x 2.5inch SASSATA no upgrades
e 8x 2.5inch NVMe supports field upgrades to 16 or 24 drives
f 16x 2.5inch NVMe supports field upgrades to 24 drives
g 24x 2.5inch NVMe no upgrades
h 8x 2.5inch NVMe 8x 2.5inch SASSATA supports upgrade to 16x SASSATA
i 8x 2.5inch NVMe 16x 2.5inch SASSATA no upgrades
Mid drive bays:
a 4x 3.5inch hotswap SASSATA drive bays
b 8x 2.5inch hotswap SASSATA drive bays
c 8x 2.5inch hotswap NVMe drive bays
Rear drive bays:
a 4x 3.5inch hotswap SASSATA drive bays
b 4x 2.5inch hotswap SASSATA drive bays
c 4x 2.5inch hotswap NVMe drive bays

CONTROLLER OPTIONS:
6 Gbps SATA controllers:
Onboard AHCI nonRAID Intel RSTe RAID
12 Gb SASSATA RAID controllers:
ThinkSystem RAID 5308i PCIe 12Gb Adapter
ThinkSystem RAID 7308i 1GB Cache PCIe 12Gb Adapter
ThinkSystem RAID 7308i 2GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 9308i 2GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 93016i 4GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 93016i 8GB Flash PCIe 12Gb Adapter
12 Gb SASSATA nonRAID HBAs:
ThinkSystem 4308i SASSATA 12Gb HBA
ThinkSystem 43016i SASSATA 12Gb HBA
NVMe PCIe interfaces nonRAID:
ThinkSystem 8104P NVMe Switch Adapter
ThinkSystem 16104P NVMe Switch Adapter

IO EXPANSION:
Riser 1: Slots 1, 2 and 3 all FHHL or FHFL 16 or 32 lanes:
a Option 1: x16, x8, x8 all physically x16 slots
b Option 2: x16, x16, NC slot 3 not connected
c Option 3: NC, NC, x16 1U riser; slot 1 and slot 2 not connected
d Option 4: x16, NC, NC slot 2 and slot 3 not connected
Riser 2: Slots 4, 5, and 6 slot size varies 32 lanes
a Option 1: x16, x8, x8 all physically x16 slots
b Option 2: x16, x16, NC slot 6 not connected
d Option 3: NC, NC, x16 1U riser; slot 4 and slot 5 not connected
Riser 3: Slots 7 and 8 both FHHL or FHFL 16 or 32 lanes
a Option 1: x8, x8 both physically x16 slots
b Option 2: x16, x16
Slot 9: Internal PCIe 4.0 x8 lowprofile slot for internal drive controller physically a x16 slot
WARNING:
The use of 32 lanes with Riser 1 or the use of Riser 3 or Slot 9 imposes restrictions on the use of the onboard SATA
controller or the use of the M.2 Module or both
NETWORK ADAPTERS:
Network adapters options:
1 Gb Ethernet
10 Gb Ethernet
PCIe Low Profile adapters 25 Gb Ethernet
InfiniBand
SAS adapters for external storage:
SAS HBAs
ThinkSystem 4308e SASSATA 12Gb HBA
ThinkSystem 43016e SASSATA 12Gb HBA
External RAID adapters
ThinkSystem RAID 9308e 4GB Flash PCIe 12Gb Adapter

GPU adapter:
ThinkSystem NVIDIA Tesla V100 16GB PCIe Passive GPU
ThinkSystem NVIDIA Tesla V100 32GB PCIe Passive GPU
ThinkSystem NVIDIA Tesla T4 16GB PCIe Passive GPU

POWER SUPPLIES:
1 or 2 ThinkSystem 550W 230V115V Platinum HotSwap PSU
1 or 2 ThinkSystem 750W 230115V Platinum HotSwap PSU
1 or 2 ThinkSystem 1100W Platinum HotSwap PSU
1 or 2 ThinkSystem 1600W Platinum HotSwap PSU

ZA VEC INFORMACIJ OBIŠČITE STRAN:


ZA PONUDBO KLIKNITE POLJE ELIM PONUDBO

ZA POMOî NAS POKLICITE ALI PA NAM POáLJITE EMAIL

Dodatne informacije

Dodatne informacije

Vrsta rack
Procesor AMD
Število jeder Ne
Višina ohišja Ne
Št. procesorjev Ne
Format diskov Ne
Število diskov Ne
Razpoložljivost artikla Po naročilu